Options and extensions for Differential Dynamic Scale Loop (DSL)
- Extended pressure range "Medium pressure"
-
Extension of standard pressure range of 45 bar (700 psi) to 172 bar (2.500 psi)
Art.-No.: P114-0003
- Extended pressure range "High pressure"
-
Extension of standard pressure range of 45 bar (700 psi) to 380 bar (5.500 psi)
Art.-No.: P114-0002 (Article P114-0003 automatically included)
- Multi Inlet Extension
-
Use of two additional sample or cleaning fluids
→ Automatic tests with 7 fluids (instead of 5)
→ Scale-on-scale test
→ Extended inhibitor testing
→ Extended dissolver testingArt.-No.: P114-0019 (Link: Data sheet Multi Inlet Extension, PDF)
- Filter blockage / Sample chamber
-
Additional sample chamber for the use of:
→ Filter with different pore size to test for filter blockage
→ Plates for the retrieval of scale material for external tests (XRD, Raman etc.)Art.-No.: P114-0004
- Flow Meter
-
High precision flow meter for continuous observation and logging of flow rate
→ Permanent validification of pump functions for more reliable test results
→ Simultaneous density measurement of the fluidArt.-No.: P212-0002
- Inline pH probe
-
Determination of pH value of the sample fluid in the outlet (pressure-free section)
→ pH range: 0 .. 14Art.-No.: P114-0005
- Inline EC probe
-
Determination of electrical conductivity of the sample fluid in the outlet (pressure-free section)
→ EC range: 1000 mS/cm
→ Max. salinity: 70 g/lArt.-No.: P114-0006
- Pneumatic suction support
-
The sample bottles are set to slight overpressure
→ Easier suction of samples
→ Remaining small air bubbles in feed lines don't cause pump failures
→ Use of inert gas to run oxidation sensitive samples (e.g. Fe(II) )Art.-No.: P114-0018
- H2S compatibility (Partially)
-
Exchange of all parts in contact with fluids (test capillary, tubing, sensors, valves)
in the pressurized heated section (oven) to H2S resisting material (e.g. Hastelloy, titanium)
→ Run even highly corrosive samples, e.g. with low H2S contentArt.-No.: P114-0023
- H2S compatibility (Full)
-
Exchange of all parts in contact with fluids (test capillary, tubing, sensors, valves)
in the complete pressurized section to H2S resisting material (e.g. Hastelloy, titanium)
→ Run even highly corrosive samples, e.g. with H2S contentArt.-No.: P114-0016
- Low temperature
-
Exchange of oven against a refrigerated thermostat
→ Measure at temperature at or below room temperature
→ Fast exchange on site possible = direct adaption to test parameters by operator
→ The thermostat can be ordered instead of the oven or in addition to itArt.-No.: P203-0013
- Extended pressure range "Medium pressure"
-
Extension of standard pressure range of 45 bar (700 psi) to 172 bar (2.500 psi)
Art.-No.: P114-0003
- Extended pressure range "High pressure"
-
Extension of standard pressure range of 45 bar (700 psi) to 380 bar (5.500 psi)
Art.-No.: P114-0002 (Article P114-0003 automatically included)
- Multi Inlet Extension
-
Use of two additional sample or cleaning fluids
→ Automatic tests with 7 fluids (instead of 5)
→ Scale-on-scale test
→ Extended inhibitor testing
→ Extended dissolver testingArt.-No.: P114-0019 (Link: Data sheet Multi Inlet Extension, PDF)
- Filter blockage / Sample chamber
-
Additional sample chamber for the use of:
→ Filter with different pore size to test for filter blockage
→ Plates for the retrieval of scale material for external tests (XRD, Raman etc.)Art.-No.: P114-0004
- Flow Meter
-
High precision flow meter for continuous observation and logging of flow rate
→ Permanent validification of pump functions for more reliable test results
→ Simultaneous density measurement of the fluidArt.-No.: P212-0002
- Inline pH probe
-
Determination of pH value of the sample fluid in the outlet (pressure-free section)
→ pH range: 0 .. 14Art.-No.: P114-0005
- Inline EC probe
-
Determination of electrical conductivity of the sample fluid in the outlet (pressure-free section)
→ EC range: 1000 mS/cm
→ Max. salinity: 70 g/lArt.-No.: P114-0006
- Pneumatic suction support
-
The sample bottles are set to slight overpressure
→ Easier suction of samples
→ Remaining small air bubbles in feed lines don't cause pump failures
→ Use of inert gas to run oxidation sensitive samples (e.g. Fe(II) )Art.-No.: P114-0018
- H2S compatibility (Partially)
-
Exchange of all parts in contact with fluids (test capillary, tubing, sensors, valves)
in the pressurized heated section (oven) to H2S resisting material (e.g. Hastelloy, titanium)
→ Run even highly corrosive samples, e.g. with low H2S contentArt.-No.: P114-0023
- H2S compatibility (Full)
-
Exchange of all parts in contact with fluids (test capillary, tubing, sensors, valves)
in the complete pressurized section to H2S resisting material (e.g. Hastelloy, titanium)
→ Run even highly corrosive samples, e.g. with H2S contentArt.-No.: P114-0016
- Low temperature
-
Exchange of oven against a refrigerated thermostat
→ Measure at temperature at or below room temperature
→ Fast exchange on site possible = direct adaption to test parameters by operator
→ The thermostat can be ordered instead of the oven or in addition to itArt.-No.: P203-0013
Do you need other technical specifications or completely other options for your application?
Contact us! Your special customization may only be a short question away.